In this case, while INT terminal (FLAG_P register) is hold, PROX value will be updated with result of
judgment for detection/non-detection of object.

8.Average consumption current in operation
8.1. Average consumption current in operation
Average consumption current in operation is the sum of the average current consumption value with Vcc
terminal and LED consumption. The LED driven current flows from LEDA terminal to GND terminal.

Japanese

この場合、外部割込み(INT)端子(FLAG_Pレジスター)がホールドされている間に、対象物の検出/非検出判定結果でPROX値が更新されます。

8.  動作中の平均消費電流
8.1 動作中の平均消費電流
動作中の平均消費電流は、Vcc端子での平均電流値とLED消費電流の合計で表わされます。LED駆動電流はLEDA端子からGND端子へと流れます。