Valve bias regulation
To replace the new valves, the user shall measure the bias of the four valves by the ampere-voltage-ohm meter. in case of deviation, adjust the variable resistance at each group of holes BIAS ADJ.(V1) BIAS ADJ.(V2) BIAS ADJ.(V3) BIAS ADJ.(V4)
by the proper tools. Turn it clockwise 0 reduce the bias, and turn it counterclockwise to increase the bias, until the bias of the four valves reaches 0.55V-0.6V at the standard voltage of 110V. Make the measurement and regulation once again after the thermal stability of the valves.
Poor power supply, no indicator on
Check the insertion of the power plug, the supply to the socket, the connection of the fuse, and power switch
バルブ・バイアス調節
新しいバルブを交換するためには、ユーザーは4つのバルブのバイアスをアンペア-電圧-オーム計で測定します。偏りがある場合、適当なツールでBIAS ADJ.(V1) BIAS ADJ.(V2) BIAS ADJ.(V3) BIAS ADJ.(V4) ホールの各群で、可変抵抗を調節してください。バイアスを減らすためには、時計廻りに0に合わせ、バイアスを増やすためには、4つのバルブのバイアスが110Vの標準電圧で0.55V-0.6Vに達するまで、反時計回りに回してください。
バルブの熱平衡後、もう一度測定と調整をしてください。
電力供給が弱く、インジケーターが消える
電源プラグの挿入、ソケットへの供給、ヒューズの接続と電源スイッチをチェックしてください。